Flame Monitors and Combustion Automation Units:

D-UG 660 Control Unit:

- 100-stage adjustable threshold
- Safety time adjustable by customer between1s and 5.5s in steps of 0.5s
- Three ranges for different adjustment of safety time and threshold
- Analogue output 0/4...20mA for transmission of the flame intensity
- Alpha numeric display to show process data and error messages in plain text
- 19“ plug-in unit

D-LX 100 Compact Flame Monitor:

- Compact design, flame sensor and control unit built as one unit
- Flame monitor for every spectral range of flame monitoring from UV to IR
- Enclosure fulfils IP 67
- Relay output contact for direct control of the fuel valve
- 10-stage adjustable threshold
- Analogue output 0/4...20mA for transmission of the flame intensity
- Safety time 1s, 3s or 5s

D-GF100, D-GF200 Programming Units:

- Control and monitoring of gas and oil burners as well as combined burners of any capacity
- Integrated flame monitor with adjustable sensitivity*
- Adjustable prepurge time
* in combination with external flame sensors of the
D-LE 103 or D-LE 603 series


High Energy Spark Ignitor:


D-HG 400:

- Ignition of liquid or gaseous fuels in high-capacity industrial burners
- Compact design: control unit and ignition lance as one modular unit
- Also available in explosion-proof execution with separate ignition lance
- Pneumatic retraction unit D-VE 500 for automatic burner ignition 


Opacity Monitor:


D-R 216:

- Double pass method (optical transmission)
- Measured values in opacity
- Adjustable limit value
- Contact switch outputs for pre-alarm and automatic cutoff system with capacity of 600 mA seconds
- Suitability tested by TÜV, approved by BMU (similar to Ministry of Environment or EPA)


Dust Concentration Meter:


D-R 280-10, D-R 281 AV:

- Double pass method (optical transmission)
- Adjustable limit value, calibration capability in mg/m3
- Adjustable limit value, calibration capability in mg/m3
- Suitability tested by TÜV, approved by BMU
- D-R 281 AV with remote panel, measured values in opacity and/or mg/m3 meets all design requirements of the US EPA, ASTM D6216-98
D-R 300:

- In-situ backscattering measurement directly in the flue gas flow
- Selectable limit values, calibration capability in mg/m3 or smoke spot number (soot)
- Automatic measuring range selection in accordance with 17. BImSchV, lowest measuring range 1 mg/m3
- Automatic dirty window correction
- Suitability tested by TÜV, approved by BMU  (similar to Ministry of Environment or EPA)


Filter Monitor:


D-FW 230, D-FW 231, D-FW 240:

- Filter monitoring based on the triboelectric  measuring principle
- Continuous in-situ baghouse monitoring
- Early detection of filter malfunction
- Selectable integration time
- Compact design, no moving parts
- Easy, straightforward installation, Service-minimal maintenance requirements
- Local display or remote control by DCS
- Explosion proof version available as D-FW 240
- Available as portable measuring system including data recording e.g. for random  sampling
- Suitability tested by TÜV, approved by BMU  (similar to Ministry of Environment or EPA) 


Volume Flow Measuring System:


D-FL 100:

- Flow rate measurement according to the principle of differential pressure
- Evaluation with the D-FL 100-10 microprocessor unit (optional)
- Suitability tested by TÜV, approved by BMU (similar to Ministry of Environment or EPA)
D-FL 200:

- Flow rate measurement according to the ultrasonic principle
- Suitable for locations with low gas velocities or aggressive gases
- Easy to install at longer measuring distances
- Suitability tested by TÜV, approved by BMU (similar to Ministry of Environment or EPA)


Emission Evaluator:


D-MS 285 / D-MS 500:

- Emission monitoring to TA-Luft, 13. and 17. BlmSchV
- The D-MS 285/500 Computerized Emission Evaluators continuously monitor the emission data of furnace plants, in accordance with the Ordinance on Large Furnace Plants and the Technical Instructions for Maintaining Air Purity (TA Luft)
- The range of application covers: fossil Ze-combustion plants, garbage incinerator plants, sludge incinerators, hall air dust extraction, cement plants and others
- Suitability-tested to the Guidelines on Evaluation of Continuous Emission Monitoring
- Suitability announcement by BMU (similar to Ministry of Environment or EPA)


Enviromental and Process Data Management System:


D-EVA / EFÜ: